跳转到主内容
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

ATTO FibreBridge 报告错误: ONTAP EMS 日志中的 FC 端口 FC_Portx 脱机

Views:
36
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
hw
Last Updated:

适用于

  • MetroCluster
  • ATTO 7500N FibreBridge
  • ATTO FibreBridge 事件日志中不支持的 SFP 消息
    • INFO Unqualified SFP (0x00000002) on FC Port x

问题

  • ATTO 网桥上的一个 FC 端口报告脱机时出现以下错误:

[hostname: dsbridge_admin: fc.bridge.fc.port.alert:alert]: Fibre Channel FibreBridge7500N Bridge ATTO_200000xxxxxxx4c0 S/N: FB7500Nxxxxxx WWN: 200000xxxxxxxxx FC Port FC_PORT1 offline.

[hostname: schmd: hm.alert.raised:alert]: Alert Id = StorageBridgePortDown_Alert , Alerting Resource = 210000xxxxxxxxx raised by monitor system-connect

[hostname: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: StorageBridgePortDown_Alert[210000xxxxxxxxx].

  • storage bridge show -fields fc-port-index-list,fc-port-oper-state-list 将一个 FC 端口显示为脱机:

示例:
name              fc-port-index-list fc-port-oper-state-list
----------------- ------------------ -----------------------
ATTO_200000xxxxxxx4c0    1,2   offline,online <<<< FC port 1 offline
ATTO_200000xxxxxxx480   1,2   online,online
2 entries were displayed.

 

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support