问题

  • 无法将 ATTO FibreBridge 添加到带内监控和 失败并显示 ""Error: command failed: entry doesn't exist

ClusterA::> storage bridge add -address 0.0.0.0 -managed-by in-band -name ATTO_FibreBridge7500N_3
Error: command failed: entry doesn't exist

  • sktrace 日志显示以下消息
 KSMF_SMF_SVC_NORM: process_request: Processing for table kern_storage_bridge took 10000 msec which is longer than the client's timeout of 5000 
  • 可能存在性能问题:
    • 它们将在 Network Processing 中的 Unified Manager , CPU nbladeNetwork 列中注明 qos statistics volume latency show:
    •  ::> qos statistics volume latency show -volume vol1 -vserver svm1 -iterations 3 Workload ID Latency Network Cluster Data Disk QoS NVRAM Cloud FlexCache SM Sync --------------- ------ ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- -total- - 4.33s 4.33s 195.00us 468.00us 0ms 0ms 0ms 0ms 0ms 0ms vol1-wid17759 17759 4.33s 4.33s 195.00us 468.00us 0ms 0ms 0ms 0ms 0ms 0ms -total- - 9.26s 9.26s 141.00us 17.00us 0ms 0ms 0ms 0ms 0ms 0ms vol1-wid17759 17759 9.26s 9.26s 141.00us 17.00us 0ms 0ms 0ms 0ms 0ms 0ms -total- - 9.26s 9.26s 141.00us 25.00us 0ms 0ms 0ms 0ms 0ms 0ms vol1-wid17759 17759 9.26s 9.26s 141.00us 25.00us 0ms 0ms 0ms 0ms 0ms 0ms 

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support