跳转到主内容

如何确认 AltaVault 驱动器需要更换

Views:
11
Visibility:
Public
Votes:
0
Category:
not set
Specialty:
not set
Last Updated:

适用于

  • AltaVault
  • AVA-400
  • AVA-800

说明

  • 在以下情况下, AltaVault 驱动器可能会报告为 " 故障 " ,并显示以下错误消息 实际处于 " 创建 " 状态
    AVADSF:AltaVault Notification from [node name] (Disk Failed: Shelf S/N [serial number], Slot [number], Model [AVA model], Disk S/N [serial number]) ALERT
  • 系统执行诊断测试时会发生这种情况 对驱动器执行操作
  • 如果驱动器通过,它将报告为 "build" ,并在完成后重新添加到 RAID 组 
    • 成功完成后,驱动器将显示为联机
  • 如果驱动器发生故障,则会报告为 " 发生故障 "

 