跳转到主内容

OCI 运行状况页报告异常检测引擎: " 错误:无法监控作业 "

Views:
27
Visibility:
Public
Votes:
0
Category:
oncommand-insight
Specialty:
oci
Last Updated:

适用场景

  • OnCommand Insight ( OCI ) 7.3.8+
  • 异常检测引擎( ade )

问题描述

  • OCI 运行状况页报告异常检测引擎: "ERROR: Failing to monitor job(s)"
  • prelet.log位于的中可能存在以下输出 <install_drive>Program Files\SANscreen\wildfly\standalone\log

2020-04-07 09:03:09,572 ERROR PrelertRetryUtil - Failure of attempt 1 of request of type FLUSH_ML_JOB following delay of 0 milliseconds. Request will be tried again after delay of 0 milliseconds.
java.util.concurrent.ExecutionException: org.apache.http.ConnectionClosedException: Connection closed

[truncated]

2020-04-07 09:03:09,614 ERROR PrelertRetryUtil - Failure of attempt 2 of request of type FLUSH_ML_JOB following delay of 0 milliseconds. Request will be tried again after delay of 4000 milliseconds.
java.util.concurrent.ExecutionException: java.net.ConnectException: Connection refused

[truncated]

2020-04-07 09:03:44,578 ERROR PrelertClient - Failed to add data to Anomaly Detection Engine for <job_name>. Http status response: HTTP/1.1 409 Conflict.

  • ADE 命令行界面中的以下命令输出将至少报告一个失败的作业。

curl -X GET "localhost:9200/_xpack/ml/anomaly_detectors/_stats?pretty"

[truncated]

"state" : "failed",
"assignment_explanation" : ""

[truncated]

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.
Scan to view the article on your device