跳转到主内容

为什么性能事件的时间戳与初始通知时间戳不同?

Views:
2
Visibility:
Public
Votes:
0
Category:
active-iq-unified-manager
Specialty:
OM
Last Updated:

适用场景

Active IQ Unified Manager ( AIQUM ) 9.6 及更高版本

问题解答

Unified Manager 中的性能事件(也称为持续事件)涉及一个监控期间,选定计数器必须在一段时间内保持高于阈值。此默认监控期间为 60 分钟。首次违反阈值时,事件在事件管理表中不可见,也不会发送通知。如果仍违反阈值且监控期限已过,则事件将在事件管理表中可见并触发通知。事件管理表中显示的时间戳是从违反阈值( " 首次查看 " )的第一个清单收集派生的,而通知将在监控期过后发出。 

追加信息

附加信息 _text

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.