跳转到主内容

由于发现网桥, Active IQ Unified Manager MetroCluster 监控失败

Views:
19
Visibility:
Public
Votes:
0
Category:
active-iq-unified-manager<a>Active IQ Unified Manager</a><a>采集问题描述</a>
Specialty:
om
Last Updated:

适用场景

  • Active IQ Unified Manager 9.7%
  • 延伸型 MetroCluster 系统

问题描述

一个或多个 MetroCluster 集群持续出现故障,监控状态保持为 " 失败 "

中出现错误 au.log

INFO  [oncommand] [collection-completion-0] [c.n.d.i.m.MccFabricConfigDiscoveryHandler] MetroCluster discovery started for clustername
ERROR [oncommand] [collection-completion-0] [c.n.d.i.m.MccFabricConfigDiscoveryHandler] MetroCluster monitoring failed for clustername

中出现错误 ocumserver.log

2020-04-07 08:16:17,963 ERROR [oncommand] [reconcile-3] [trtnas02mp(incremental@08:16:15.965)] [c.n.dfm.collector.OcieJmsListener] Inventory change listener error
com.netapp.dfm.ontap.outbound.zapi.OcumMonitoringFailedException: could not execute batch
Caused by: org.hibernate.exception.ConstraintViolationException: could not execute batch...

Caused by: java.sql.BatchUpdateException: (conn=673) Duplicate entry '16069-2131000011' for key 'nodebridgeconnection.NodeBridgeConnection_NodeId_BridgeId_UQ'...
Caused by: java.sql.SQLIntegrityConstraintViolationException: (conn=673) Duplicate entry '16069-2131000011' for key 'nodebridgeconnection.NodeBridgeConnection_NodeId_BridgeId_UQ'
 ...
Caused by: java.sql.SQLException: Duplicate entry '16069-2131000011' for key 'nodebridgeconnection.NodeBridgeConnection_NodeId_BridgeId_UQ'

然后是

2020-04-07 08:16:17,963 ERROR [oncommand] [reconcile-3] [trtnas02mp(incremental@08:16:15.965)] [c.n.dfm.collector.OcieJmsListener] Inventory change listener error
org.springframework.dao.DataIntegrityViolationException: could not execute batch; SQL [insert into NodeBridgeConnection (resourceKey, objVersion, objectName, healthStatus, bridge_id, cluster_id, node_id, id) values (?, ?, ?, ?, ?, ?, ?, ?)]; constraint [nodebridgeconnection.PRIMARY]; nested exception is org.hibernate.exception.ConstraintViolationException: could not execute batch


注:Unified Manager 日志文件位置

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.