跳转到主内容

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

重命名源卷会在 Commvault 中导致自动复制失败

Views:
27
Visibility:
Public
Votes:
0
Category:
active-iq-unified-manager
Specialty:
om
Last Updated:

适用于

  • Active IQ Unified Manager 9x
  • OnCommand Unified Manager 7.3
  • Commvault IntelliSnap

问题

  • 主卷已在自动复制作业之前重命名
  • 重命名卷后,使用 OCUM 启动复制的 Commvault 无法复制此卷,因为它会抱怨原始卷缺失。
  • 在 OCUM Gul 中检查时,卷已重命名
  • 在 UM 订阅服务中,我们发现卷仍使用旧名称

Commvault 中的错误:
Error Code: [13:127]
Description: Error occurred while processing chunk [8878] in media [] for storage policy [policy name] copy [name]: .
Source: its-commserve, Process: AuxCopyMgr

Error occurred while processing chunk [8878] in media [] for storage policy [policy name] copy [name]: .
Source: its-commserve, Process: AuxCopyMgr

Error occurred while adding list
of snapshots to Dataset id [0ce429fe-4d45-4b3d-b9d7-4f9c27d1cc55:app_type=OCUM,type=storage_service_subscription,uuid=24dbd33d-b2d0-44a2-bf1b-5fee78c63222], Source Copy [100]. Error Message = [Volume containing path:[/vol/path/to/dest.lun] not present on filer:[cluster1].].Check streams information for more details
Source: gdc02168, Process: AuxCopy

 