In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

OnCommand Unified Manager 未发送预期警报

Views:
17
Visibility:
Public
Votes:
0
Category:
oncommand-unified-manager
Specialty:
om
Last Updated:

适用于

  • OnCommand Unified Manager ( UM )
  • Active IQ Unified Manager 9.5 和 9.6

问题

  • 缺少预期警报或警报间歇性出现
  • 旧警报不会被废弃,并被视为虚假警报
  • 查看Configuration -> Cluster Data SourcesOperation End Time“否”调查已完成超过 15 分钟
  • 服务器上的内存使用率非常高
  • 与以下类似的错误出现在 server_mega.log 中:

2020-03-01 01:54:25,921 ERROR [default task-15] c.o.s.s.s.OriginatorUpdateSessionEJB (OriginatorUpdateSessionEJB.java:148) - Failed in processing xml for originId: 20, dataSourceName: null: com.netapp.oci.platform.common.table.TableException: Failed to execQuery: SELECT ds.* FROM acquisition.ds ds, acquisition.originator o WHERE ds.id=o.ds_id AND o.id=20 ...
Caused by: java.sql.SQLException: Connection is closed

 