问题

您可能会注意到:
Alert: The path to the disk shelves is broken at shelf port XX:XX
 

Event: Disk Shelf Multipath Not Configured
 

要验证与此知识库文章相关的问题、请使用以下知识库文章之一收集支持捆绑包:

在支持包中、 ocumserver-debug 日志将包含以下日志条目: 


201X-XX-XX 14:44:42,946 DEBUG [oncommand] [alert-83] [c.n.dfm.impl.alert.EmailAlertAction] Sending email to [Insert_Email_Here] for alert 'Configured_Alert' with event 'disk-shelf-path-failure' for object 'Node_Name:0x:x' <-(Node_name:Port#:shelf#)

On the High Availability (HA) Partner, run sysconfig -a 
The output displays as the following: 

slot 0: SAS Host Adapter 0a (PMC-Sierra PM8001 rev. C, SAS, )
 Firmware rev:     0x.1x.0x.0x
 Base WWN: 5:00a098:0036d0f:eX
 Phy State:      [0] Enabled, 6.0 Gb/s
           [1] Enabled, 6.0 Gb/s
           [2] Enabled, 6.0 Gb/s
           [3] Enabled, 6.0 Gb/s
 QSFP Vendor:     available, but not valid
 QSFP Part Number:   available, but not valid
 QSFP Type:      available, but not valid
 QSFP Serial Number: available, but not valid

 