当出现其中一个时, OCUM 无法监控集群 节点处于不合格状态

Views:
20
Visibility:
Public
Votes:
0
Category:
active-iq-unified-manager
Specialty:
om
Last Updated:

适用于

  • Active IQ Unified Manager ( OCUM ) 9.x
  • OnCommand Unified Manager (OCUM) 9.x

问题

  • 集群监控失败事件将显示在 OCUM 中 Web UI
  • 中存在以下错误 ocumserver.log
2020-08-12 05:57:04,193 ERROR [umadmin] [job-326] [refresh(cluster=%cluster_name%)|forceAcquisition] [com.netapp.dfm.job.JobEngine] Error executing job 929c0a0fc57e14bc:1c44b14f:173d8837f89:-7f9f task 929c0a0fc57e14bc:1c44b14f:173d8837f89:-7fa1: Errors reported on acquisition with start time 05:56:35.844: [storage-shelf-list-info; errno: 14007, reason: Node is not healthy, storage-adapter-get-adapter-info; errno: 14007, reason: Node is not healthy]
  • 以下输出显示在 ONTAP 命令行界面中

cluster1::*> cluster show

Node                 Health  Eligibility   Epsilon

-------------------- ------- ------------  ------------

cluster1-a        true    true          true

fcluster1-b       true    true          false

fcluster1-c      false   false         false

cluster1-d     true    true          false

4 entries were displayed.

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support