问题

由于 vCenter 上存在重复的 UUID ,因此 ActiveIQ Unified Manager 上的虚拟机不能使用 IOPS 和延迟

/var/log/ocie/au.log上,您将看到类似的条目、分别对应重复的磁盘和实例( BIOS UUID )

2020-04-17 00:07:35,303 WARN  [pool-3-thread-4450] c.o.s.a.d.v.b.VirtualDiskBuilder (VirtualDiskBuilder.java:176) - Virtual disk Instance [scsi0:0] belonging to vm [vm-157] and Virtual disk Instance [scsi0:0] belonging to vm [vm-673] are having the same UUID [6000C294-a3f9-b05e-1b3a-1020a040c40c] for vcenter [vcenter.example.com]. Only one of them gets updated in the virtualdisk table. Kindly resolve the UUID duplication issue from vCenter for both the entries to be included.


2020-04-17 16:04:06,203 WARN  [pool-3-thread-10154] c.o.s.a.d.v.b.VmBuilder (VmBuilder.java:158) -  VM moid s [vm-72844] and [vm-70779] are having the same instance UUID [423e42c9-2694-ab47-651e-6869bc40452e] for vcenter [vcenter.example.com].  Only one of them gets updated in the vm table. Kindly resolve the UUID duplication issue from vCenter for both the entries to be included.

 