In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

Active IQ Unified Manager 9.7 错误 "The MYSQL8 service on Local Computer started and then stopped" 。

Views:
8
Visibility:
Public
Votes:
0
Category:
active-iq-unified-manager
Specialty:
om
Last Updated:

适用场景

Active IQ Unified Manager 9.7 ( AIQUM )

问题描述

  • Active IQ Unified Manager 9.7P1 MySQL 8 服务启动和停止,并显示错误:

"The MYSQL8 service on Local Computer Started and then stopped. Some services stop automatically if they are not in use by other services or programs"

  • 在 mysql/error.log 中发现错误:

[ERROR] [InnoDB] Combined size of log files must be < 512 GB
[ERROR] [Server] Plugin 'InnoDB' init function returned error.
[ERROR] [Server] Plugin 'InnoDB' registration as a STORAGE ENGINE failed.
[ERROR] [Server] Failed to initialize builtin plugins.
[ERROR] [Server] Aborting

 

 