跳转到主内容

BMC固件升级停留在5%处、并且未进行

Views:
6
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2009年294437</a>
Last Updated:

适用场景

问题描述

  • 从ONTAP升级BMC固件时、停留在5%、并且未继续

cluster::>system service-processor image update-progress show
         In               Percent
Node        Progress Start Time      Done   End Time
---------------- -------- ------------------- ------- -------------------
clujster1-01   yes    17/10/2022 11:43:07  5     -
clujster1-02   no    -           0     -
2 entries were displayed.

  • AutoSupport中的SP-MGMT-MLOG-TXT.GZ显示更新正在启动、但停留在"无法获取固件更新进度"
... 11:43:07 +00:00 [kern_servprocd:info:6569] 0x808ac9b00: 0: NOTICE: Servprocd::SpUpdate: SpUpdateReport: New SP package 13.7 is available on local node. ... 12:02:17 +00:00 [kern_servprocd:info:6569] 0x809428a00: 8003e80000258cf3: NOTICE: Servprocd::SpUpdate: InstallSpPckg: Removing /mroot/etc/RLM_FW ... 12:02:17 +00:00 [kern_servprocd:info:6569] 0x809428a00: 8003e80000258cf3: NOTICE: Servprocd::SpUpdate: InstallSpPckg: Installing /mroot/etc/software/BMC_FW_308-04115_13.7.zip ... 12:02:17 +00:00 [kern_servprocd:info:6569] 0x809428a00: 8003e80000258cf3: NOTICE: Servprocd::SpUpdate: InstallSpPckg: SP firmware package /mroot/etc/software/BMC_FW_308-04115_13.7.zip has been installed. ... 12:02:17 +00:00 [kern_servprocd:info:6569] 0x809428a00: 8003e80000258cf3: ERR: Servprocd::SpUpdate: doPreUpdateChecks: In function - SpCPMIUpdateOp::doPreUpdateChecks() ... 12:02:17 +00:00 [kern_servprocd:info:6569] 0x809428a00: 8003e80000258cf3: NOTICE: Servprocd::SpUpdate: doPreUpdateChecks: BMC update - Pre-update checks passed. ... 12:02:17 +00:00 [kern_servprocd:info:6569] 0x809428a00: 8003e80000258cf3: NOTICE: Servprocd::SpUpdate: UpdateSmfState: processing ck_update_cli_scheduled. ... 12:02:17 +00:00 [kern_servprocd:info:6569] 0x80942cb00: 0: NOTICE: Servprocd::SpUpdate: set_bmc_state_cpmi: updated BMC status - 8. ... 12:02:22 +00:00 [kern_servprocd:info:6569] 0x80942cb00: 0: NOTICE: Servprocd::SpUpdate: servprocd_trigger_fw_update_cpmi: cpmi_set_fw_update_info(16) suceeded. ... 12:02:22 +00:00 [kern_servprocd:info:6569] 0x80942cb00: 0: NOTICE: Servprocd::SpUpdate: update: BMC update has been successfully triggered. ... 12:02:52 +00:00 [kern_servprocd:info:6569] 0x80942cb00: 0: NOTICE: Servprocd::SpUpdate: monitorUpdate: Waiting for BMC update to complete. Monitor count=(0), sleep 30 seconds... ... 12:02:52 +00:00 [kern_servprocd:info:6569] 0x80942cb00: 0: ERR: Servprocd::SpUpdate: servprocd_cpmi_get_fw_update_info: cpmi_get_fw_update_info(0x10) Failed. ... 12:02:52 +00:00 [kern_servprocd:info:6569] 0x80942cb00: 0: ERR: Servprocd::SpUpdate: monitorUpdtPrgrs: unable to get firmware update progress.
  • 在尝试下载软件包时、AutoSupport中的apache-access.GZ将显示302返回代码

192.0.2.81 192.0.2.84 4294967295/4294967288 - [Mon Dec 05 12:46:48.088423 2022 +0000] "GET /FW_BMC/CPMI_BMC.ima HTTP/1.1"302 1264 3886 - 0 - - -

  • 以下行将继续重复、直到操作超时或重新启动BMC为止
... 12:02:52 +00:00 [kern_servprocd:info:6569] 0x80942cb00: 0: NOTICE: Servprocd::SpUpdate: lookup_bmc_updt_str: BMC update - Triggered but not started.(0x0) ... 12:03:22 +00:00 [kern_servprocd:info:6569] 0x80942cb00: 0: NOTICE: Servprocd::SpUpdate: monitorUpdate: Waiting for BMC update to complete. Monitor count=(X), sleep 30 seconds... ... 12:03:22 +00:00 [kern_servprocd:info:6569] 0x80942cb00: 0: ERR: Servprocd::SpUpdate: servprocd_cpmi_get_fw_update_info: cpmi_get_fw_update_info(0x10) Failed.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.